Archives

March 7, 2014

11596-090

2 Slot 2U ATCA Chassis with Triple-Replicated-Mesh Backplane and 40Gbps data transfer rate, IPMB bussed

Conforms to AdvancedTCA Specification PICMG 3.0 Rev. 2.0, NEBS ready, UL recognized
AdvancedTCA 2 Slot 2U horizontal Central Office Shelf
40Gbps 2 Slot backplane with triple-replicated-mesh topology
DC Power, two redundant Power Entry-Modules (PEM) for -48VDC/ -60VDC
Push-pull cooling, two redundant Hot-swapable fan trays for cooling up to 200W per Front Board and 30W per RTM
Two redundant Shelf Managers based on Pigeon Point ShMM-500 technology
Shelf Alarm Panel (SAP)

March 7, 2014

AdvancedTCA 6U System w/ redundant cooling

This 6U AdvancedTCA Chassis features full redundancy with dual redundant fan trays, shelf managers, and A/C power supplies. The shelf managers and A/C power are optional. Side-to-side cooling is achieved via a plug-in fan tray with dual 170 CFM fans with PWM (pulse width modulation) control on each side of the card cage. The redundant push/pull configurations of the fans offer higher levels of reliability.
The N+1 version offers two 1200W power supplies as well as optional dual shelf management integration. The chassis is ideal for designs that need the high-performance and functionality of ATCA, but prefer AC power supply options.

FEATURES:
– 19″ rack mount, fully compliant to PICMG 3.0
– 6U H x 444mm W x 385mm D
– Rugged steel Construction
– Fits into Zone 4 Seismic Rack (NEBS 3)
– 6 slot full mesh backplane connectivity
– Single or dual 1200W AC input PSU providing 48V @ 25A
– Dual fan trays on each side of the card cage
– Side-to-side cooling in push-pull configuration, redundant cooling
– Single or dual pluggable ATCA Shelf manager optional

March 7, 2014

AdvancedTCA 5U System w/ Redundant cooling

This 5U AdvancedTCA Chassis features full redundancy with dual redundant fan trays, shelf managers, and A/C power supplies. The shelf managers and A/C power is optional. Side-to-side cooling is achieved via a plug-in fan tray with dual 170 CFM fans with PWM (pulse width modulation) control on each side of the card cage. The redundant push/pull configurations of the fans offer higher levels of reliability.
The new N+1 version offers two 700W or 1200W power supplies as well as optional dual shelf management integration. The chassis is ideal for designs that need the high-performance and functionality of ATCA, but prefer power supply options.

FEATURES:
– 19″ rack mount, fully compliant to PICMG 3.0
– 5U H x 444mm W x 385mm D
– Rugged steel Construction
– Fits into Zone 4 Seismic Rack (NEBS 3)
– 5 slot full mesh backplane connectivity
– Single or dual 700W AC input PSU providing 48V @ 15A
– Dual fan trays on each side of the card cage
– Side-to-side cooling in push-pull configuration, redundant cooling
– Single or dual pluggable ATCA Shelf manager optional