Archives

October 5, 2016

VT830

The VT830 features dual Switching Shelf Managers (SSMs) that combines VadaTech’s 3rd Generation Shelf Manager with integrated GbE/10GbE/40GbE switches on the same module. This allows two slots in the system to be used as Nodes (Payload Boards) versus having the slots otherwise be allocated as dedicated switching Hubs in the system.

The 6U 6-slot SlotSaver ATCA Chassis conforms to the latest PICMG 3.0 specification in 10G or 40G configurations. The Shelf has a 19″ rackmount form factor compliant to EIA-310. The VT830 Shelf offers 10GbE/1GbE Layer 2 managed switches or 40GbE/10GbE/1GbE Layer 3 managed switches. The Switching Shelf Managers have RTM capabilities for rear I/O.

The AC input of the Shelf provides N+1 redundancy, with options for DC or AC/DC combined configurations. The 6U ATCA Shelf offers exceptional thermal management with each slot dissipating up to 375W in a redundant push/pull configuration. The fan trays and air filters are all separately removable.

July 30, 2014

AdvancedTCA C06-6U-AC

-Highly efficient packaging with 450W+ per slot cooling in horizontal 6U form factor
-RTM cooling 45W per slot
-2 hot swap high end fan units
-Quiet fans under no-failure conditions
-19″ Rack mounted 6-U system
-AC Input AdvancedTCA Version
-6 slot horizontal front boards and RTM
-6 slot high performance Backplane, with DualStar or Full Mesh fabric connections
-40GBASE-KR4 and 10GBASE-KR4
-Cable tray on rear side
-Two versions of AdvancedTCA controller with different stages of intelligence
-Redundant System Controller / ShMC
-Up to four N+1 Redundant power supplies
-Power supply: 48DC output, 850W@90V-250V
-High Reliability bussed IPMI
-Fully PICMG 3.0 Rev 2.0 compatible
-Designed for compliance to NEBS and EN levels

July 29, 2014

AdvancedTCA CO2-3U

-19′ Rack mounted 3U AC/DC Economy Version
-2 slot replicated full mesh Backplane
2 slot horizontal for ATCA Front- and RTM Boards
-Redundant 48V DC PEM & EMC filtered power feeds or Redundant Dual 850W AC Power Supply
-Push-pull cooling hot-swap & redundant Fan Trays
-Dedicate RTM cooling
-Fully PICMG 3.0 Rev 2.0 compatible
-Designed for NEBS/ETSI compliance, RoHS
-High Reliability bussed IPMI
-Side to Side cooling
-Highly efficient packaging with up to 300W per slot cooling in horizontal 3U form factor
-RTM cooling 30W per Slot
-High performance Backplane exceeds AdvancedTCA specification
-2 hot swap fan units
-Removable Air gilter on air inlet side
-Controller is compatible with CO2 and CO6 horizontal systems