Archives

October 5, 2016

VT951

The VT951 is a rugged 1U chassis used in Mil/Aero or other applications that need to withstand shock/vibration. The lightweight aluminum construction provides 6 single module mid-size AMC slots. For front panel retention, there is a single MicroTCA.1 screw on the opposite side of the ejector handle on each module slot. The chassis offers dual redundant PSUs, hot-swappable from the rear of the chassis.

The front-to-rear cooled chassis utilizes the VadaTech 3rd generation MCH (UTC004 product) for its shelf manager, crossbar clocking for low jitter, GPS/IEEE1588/SyncE/NTP, etc. The VT951 has PCIe Gen3 dual x4 or single x8 routed to each AMC slot.

The VT951 backplane provides direct connection between adjacent AMC slots on ports 2-3 and on ports 12-20.

October 5, 2016

VT898

The VT895 is a 6U μTCA chassis that provides 12 AMC full-size, double module slots that can accept any AMC.1, AMC.2, AMC.3 and/or AMC.4.

The VT895 has full redundancy, including redundant MCH, Power Modules, as well as redundant Cooling Units (CU) for high availability. The cooling configuration is from bottom-to-top. There is an option for redundant/non-redundant clock per μTCA specification. It provides CLK1, CLK2, and CLK3 to each slot. The CLK3 option can be configured for the Fabric clock as well as Telecom clock.

An option is available for Port 2 and 3 to be directly connected among the adjacent AMCs or to the fabric B (AMC.3 SATA/SAS switch option on the MCH). The chassis routes ports 12-15 and 17-20 to each slot.

The VT895 has a rear Telco Alarm as well as Redundant FRU information devices and carrier locators. A JTAG Switch Module (JSM) slot routes to the JTAG port of each AMC.

October 5, 2016

VT895

The VT895 is a 6U μTCA chassis that provides 12 AMC full-size, double module slots that can accept any AMC.1, AMC.2, AMC.3 and/or AMC.4.

The VT895 has full redundancy, including redundant MCH, Power Modules, as well as redundant Cooling Units (CU) for high availability. The cooling configuration is from bottom-to-top. There is an option for redundant/non-redundant clock per μTCA specification. It provides CLK1, CLK2, and CLK3 to each slot. The CLK3 option can be configured for the Fabric clock as well as Telecom clock.

An option is available for Port 2 and 3 to be directly connected among the adjacent AMCs or to the fabric B (AMC.3 SATA/SAS switch option on the MCH). The chassis routes ports 12-15 and 17-20 to each slot.

The VT895 has a rear Telco Alarm as well as Redundant FRU information devices and carrier locators. A JTAG Switch Module (JSM) slot routes to the JTAG port of each AMC.